EAGLE2000
— a new level of
Detection Monitoring
EagleVision
2
Software Manual
Przeglądanie stron 0
1 2 3 4 5 6 ... 75 76

Podsumowanie treści

Strona 1

EAGLE2000™ — a new level ofDetection MonitoringEagleVision™2 Software Manual

Strona 2 - WARRANTY INFORMATION

EagleVision contains menus that are used to navigate through the appli-cation and access various features.The file menu allows the operator to:“Save”

Strona 3 - SYSTEM CONFIGURATION

Driver Settings ( 3) Highway polling can be enabled or disabled. The last Modbus highway error (if any) is shown and can becleared. Counters are di

Strona 4 - ADDING GRAPHICS CAPABILITIES

The Misc menu includes the following selections:Address Check Allows the operator to get avariety of information on a par-ticular address.Hide/Show Ev

Strona 5 - Installing EagleVision

EAGLE2000™ — a new level ofDetection MonitoringSection 2System ConfigurationEvent Configuration Screen 2.1 Event Configuration (EagleVision) 2.5Even

Strona 6 - SYSTEM REQUIREMENTS

Selecting “Event Configuration ( 1)” from the “Configure” menu will dis-play the “Event Configurations” screen.This screen is used to create events t

Strona 7

There are seven buttons on the “Event Configurations” screen, which per-form a variety of functions related to the event monitor. They aredescribed be

Strona 8 - EAGLEVISION FILES

FindSelect the Find button to display the “Find” dialog box. By entering eithertext or an address in the appropriate box, the program will display the

Strona 9 - EAGLEVISION CAPABILITES

Imp/ExpThe Imp/Exp (Import/Export) button allows an external file, created inanother application, to be read into the system, or a database configured

Strona 10 - CONFIGURE MENU

1. Select Event Configurations from the Configuration menu:2. The Event Configurations screen is displayed:This screen displays the following inform

Strona 11 - EagleVision Software Overview

5. Enter the Event Type by means of the Type pop-up menu.Transition OnWhen the discrete bit specified in the PLC and address fieldschanges state from

Strona 12 - MISC MENU

ALL IMPLIED WARRANTIES ON THIS SOFTWARE PACKAGE, INCLUDINGIMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-LAR PURPOSE, ARE LIMITED IN

Strona 13 - Detection Monitoring

6. Enter the Event Name.Enter the name of the event. It will appear in the event window, indaily event logs, and when printed. The name can be up to

Strona 14

This will bring up a dialog box where the operator enters the gate-way number, point number, and then chooses the status bit from apop-up menu. After

Strona 15 - SCREEN BUTTONS

e. Auto ClearThe Auto Clear checkbox controls the requirement for operatoracknowledgment. When Auto Clear is enabled, operatoracknowledgment is not re

Strona 16

Although it is possible to build the entire event monitoring database fromwithin the EagleVision application, the operator may wish to develop thedata

Strona 17

To import a file containing all of the database records for the event moni-tor, the operator must ensure that the file follows the structure as define

Strona 18

The following is a field-by-field specification of the record structure.Field 1: Event numberMust be a number ranging from 0 to 4999.Field 2: Device a

Strona 19

Field 11: Event colorMust contain one of the following text strings:Black (5 characters)Blue (4 characters)Red (3 characters)Green (5 characters)F

Strona 20

Selecting “Print Settings” from the configure menu will bring up the print-ing configuration screen.It has a variety of icon based controls described

Strona 21

Change page titleClick on this area to bring up a dialog box allowing the header text print-ed on each page to be changed.The page title can be any co

Strona 22

Selecting “Driver Settings” from the configure menu will bring up the dri-ver configuration screen.The Driver Configuration screen allows you to confi

Strona 23

SECTION 1EagleVision Software Package...1.1 System Requirements...

Strona 24

A variety of onscreen pushbuttons and switches control the configuration.These controls are described below.Hiway PollingSwitch this off to stop reque

Strona 25 - DATABASE FILE STRUCTURE

The single port version assigns the modem port for communicating withthe gateway.The four port version leaves the modem port open and uses only the fo

Strona 26

MEMORY MAP OVERVIEWDatatable configuration defines the PLC/Gateway addresses that the OISwill read.The gateway memory accessible to the OIS emulates a

Strona 27

1. Select Datatable Configuration from the Configure menu. TheDatatable Configuration screen appears:# The datatable number is a numeric index used b

Strona 28

DATATABLE CONFIGURATIONPROCEDURE2. To set up or modify a datatable:a. Select the datatable for configuration or modificaton and selectModify.orDouble-

Strona 29 - FOUR PORT VERSION

POINT CONFIGURATIONPROCEDURE1. Select Point Configuration from the Configure menu.This brings up the point configurations screen.A “point’’ is define

Strona 30

3. The Point Configuration screen is displayed:Point numbers 1 through 4 are reserved for the gateway.4. Assign a configuration number to the curren

Strona 31 - OIS MODBUS ADDRESS

ENTERING POINT CALIBRATIONANDALARM SETPOINTSSETTING POINT UPDATE RATES7. Enter the user-defined calibration value in the appropriate units.See Units:

Strona 32 - Datatable Configuration ( )

10. To continue configuration of other points, select the point numberbox and: Select the “S” box next to the scroll arrows and enter thedesired Poin

Strona 33 - DATATABLE CONFIGURATION

1. Select the point number or name of the device needing configu-ration and then select the Modify button.orDouble-click on the point or name of the d

Strona 34 - PROCEDURE

SECTION 3Gateway Point Display...3.1General Information Indicators...

Strona 35 - Point Configuration ( )

4. Start/End Mode:The default program mode selection for the Relay Module is the“Start/End” mode. In this mode enter a “start” and “end” nodenumber an

Strona 36

The IMP/EXP button allows the operator to export an existingEagleVision point configuration database, or, to import one that hasbeen created or modifi

Strona 37 - SETTING POINT UPDATE RATES

The gateway has four relays, each of which can be configured to monitora contiguous group of points. In addition there is a gateway fault relay.All re

Strona 38 - FIND PROCEDURES

4. To configure the gateway relays, select Modify Relays. TheGateway relay configuration screen is displayed:5. The upper right area of the screen h

Strona 39

The Network Utilities portion of the Point Configurations screen allowsconfigurations to be transferred between the OIS and the gateway(s).Get Revisio

Strona 40

Upload AllSelect Upload All to upload the point configuration from the current gate-way to the OIS. The individual point names will appear as asterisk

Strona 41 - IMPORT/EXPORT

Zone ConfigurationZones are provided primarily to simplify the programming of customgraphics. They are operator configured logical groupings of up to

Strona 42 - Gateway Relay Configuration

3. To configure or edit a zone, select a zone to modify by double-click-ing on the zone of interest, or by clicking once on the zone andthen selecting

Strona 43

Zone Trigger ConfigurationAfter the zones are configured, EagleVision must be given the criteria forwhat constitutes Alarms and Faults. This is done “

Strona 44 - Network Utilities

This screen shows the status of all 256 possible zones. Unconfiguredzones are blank. Configured zones will display one of five possiblestates: Normal,

Strona 45

EAGLE2000™ — a new level ofDetection MonitoringSection 1Installing EagleVision™EagleVision Software Package 1.1 Installing EagleVision Software 1.2Me

Strona 46 - Zone Configuration ( )

The configuration overview provides a convenient display of the currentEagleVision configuration. This screen is shown at startup and can beaccessed w

Strona 47

Select Address Check to check address usage for a specific Modbusaddress. The operator enters an address to determine:1. If the address is a legal ad

Strona 48

Selecting this feature from the miscellaneous menu will invoke the“Communication Module Alarm Retrieval” dialog box. This will allow thetargeted retr

Strona 49

Launches the utility that shows a chronological list of any configuredevents that are currently out of tolerance.Launches the utility that displays th

Strona 50 - Configuration Overview ( )

EAGLE2000™ — a new level ofDetection MonitoringSection 3Point DisplaysGateway Point Display 3.1Communication Module Point Display 3.4Relay Module Po

Strona 51 - ESTORE PASSWORD PROTECTION

The Point Display screens allow the operator to monitor gateway opera-tions and perform certain control functions. The point display can also beenter

Strona 52 - PREFERENCES

LON Fault This indicator will turn red when the gate-way diagnoses a LON fault. This type offault is generally indicative of an electricalopen or shor

Strona 53 - EVENTHISTORY

Reset Relay Select a Reset Relay button to reset a gate-way relay.Goto Point This button calls up a keypad allowing theuser to go directly to any poin

Strona 54 - Point Displays

The Point Display screens allow the operator to monitor a communica-tions module/sensor operation, and perform certain control functions.1. Select the

Strona 55 - INDICATORS

Inhibit Active This indicator will turn red when the point hasbeen “inhibited” by using the point display’sinhibit button. When “inhibited” any gatewa

Strona 56

EagleVision Software PackageSYSTEM REQUIREMENTS1.1 95-8434The EagleVision Software Package includes: 1. Several disks containing EagleVision Software

Strona 57 - PUSHBUTTON FUNCTIONS

Digital Input 2 Status Shows the status of the signal connected tothe communication module’s digital input 2.Output Relay Status Shows the status of

Strona 58 - POINT DISPLAY

The sensor level bar graph provides the following real-time information: The sensor level bar graph provides a graphic display of the sen-sor’s outp

Strona 59

Com 1/Com 2 These indicators track the fault isolation statusof the module. If the left side has isolateddue to a network fault, the “Com 1” indicato

Strona 60 - ALARM HISTORY

Not Communicating The gateway has not been receiving the peri-odic status updates from the target module.Invalid Config. Invalid configuration data ha

Strona 61 - SENSOR LEVEL BAR GRAPH

EAGLE2000™ — a new level ofDetection MonitoringSection 4Adding Graphics CapabilitiesGetZoneState 4.8GetZoneStatus 4.8LogToAll 4.9LogToDisk 4.9LogToEv

Strona 62 - Relay Module Point Display

Included with the EagleVision software package are two files,”EagleVision Supercard” and ”EagleVision Hypercard.” These files con-tain a suite of XCM

Strona 63

XCMD's & XFCN'sACKEVENTSCHKEVENTSTATECLEAREVENTWINDOW4.2For use in HyperCard, they must reside in either the stack from whichthey will b

Strona 64 - Adding Graphics Capabilities

XCMD's & XFCN's4.3This command gets an event that is in the log file. The count is from thestart of the file.GetALoggedEvent(theLoggedEv

Strona 65 - XCMD AND XFCN DEFINITION

GETMANYBITGETNUMLOGGEDEVENTSXCMD's & XFCN's4.495-8434Refer to the section on addressing for the correct format of the address. Astring i

Strona 66 - CLEAREVENTWINDOW

XCMD's & XFCN's4.595-8434set the lockScreen to true— speed up getting the dataput lastEventCount into count— where do we start from

Strona 67 - GETGWPOINTDISPLAY

1. Rename the Macintosh hard disk drive “Detector.”2. Insert EagleVision Disk 1 (P/N 006141-001) into the floppy driveand double-click on the “Install

Strona 68 - GETNUMLOGGEDEVENTS

XCMD's & XFCN's4.695-8434While the operator is looking at the event log, a new event might occur.The following script checks for new eve

Strona 69

GETTABLESTATEGETWORDXCMD's & XFCN's4.795-8434This command will return the changed bit of the datatable requested.GetTableState(3)Example

Strona 70

XCMD's & XFCN'sGETZONESTATEGETZONESTATUS4.8This command will return the changed bit of the zone requested. Zones are num-bered 1-256.Get

Strona 71 - GETTABLESTATE

XCMD's & XFCN'sLOGTOALLLOGTODISKLOGTOEVENTWINDOW4.9This command “Logs” any event in a text format. This command will log the datapassed

Strona 72 - GETZONESTATUS

XCMD's & XFCN'sLOGTOPRINTERRESETBIT4.10This command “Logs” any event in a text format. This command will log the datapassed to the print

Strona 73 - LOGTOEVENTWINDOW

SETBITSETTABLEPOLLING4.1195-8434This command sets the state (1) of any single bit in the PLC. Refer to the section onaddressing for the correct format

Strona 74 - RESETBIT

SETTABLESTATESETWORDSETZONESTATE4.12This command will set the changed bit of the datatable requested.SetTableState tableNumber Example:on openCardSetT

Strona 75 - SETTABLEPOLLING

EagleVision This is the core application program, which han-dles all communication, data acquisition, loggingand system configuration.Configuration Th

Strona 76 - SETZONESTATE

Acquire data from the gateway(s)Data, in the form of 16-bit status words, can be acquired from up to fourgateways that are connected to the OIS. To sp